LaserCheck
Hand-held Laser Power Meter |
|
|
- Auto ranging with peak sample-and-hold
- Power measurement fom 0.5 µW to W
- ±5% calibrated accuracy from 400-1064 nm
|
|
Specifications
|
| Sensor Disk: |
Silicon, 8 mm aperture |
| Power Range: |
0.5 µW-1 W |
| Accuracy: |
±5% |
| Max Power Density with built-in ND attenuator: |
30 W/cm2 |
| Wavelength Range: |
400-1064 nm |
| Battery Life: |
180,000 measurements at 12 sec/sample |
| Overload Indication: |
"- - -" display and beep tone |
| Size: |
168 x 24 x 20 mm |
| Weight: |
44 g |

|
LaserMate-Q
High-sensitivity Laser Power Meter |
 |
|
- Cost-effective precision CQ low power measurement
- Range of 3 programmed sensors for 250 nm-1.8 µm
- Power measurements from 10 nW-50 m (5 W with attenuator)
|
| LaserMater-Q Sensors |
|
Description
|
Type
|
Wavelength Range (nm)
|
Power Max (mW)
|
Power Min (nW)
|
Accuracy (Including display) % of reading
|
Accuracy (Including display) ± LSD
|
Maximum W/cm2
|
Sensor Diameter (mm)
|
| LaserMate-Q Sensor, Visible |
VIS |
400-1064 |
50 |
10 |
3.5 |
2 |
1 |
7.9 |
| LaserMate-Q Sensor, Ultraviolet |
UV |
250-400 |
30 |
10 |
5 |
2 |
0.3 |
6 |
| LaserMate-Q Sensor, Infrared |
IR |
800-1800 |
10 |
10 |
5 |
2 |
0.5 |
5 |
| Specifications |
| Readout Console Specifications |
|
| Power Subtraction: |
Offset of any reading to zero |
| Display Response Time: |
<0.2s |
| Battery: |
9 V, >20 hours life |
| Display Backlighting: |
With AC operation only |
| Power Waveform Viewing |
|
Ranges
|
Frequency Response
|
| *1 mW |
50 kHz
|
|
100, 300 mW
|
5 kHz
|
|
10, 30 mW
|
500 Hz
|
|
1, 3 mW
|
50 Hz
|
|
100, 300 nW
|
5 Hz
|

|
LaserMate-P
Pulsed Laser Energy Meter |
|
|
- Cost-effective precision pulsed energy measurement
- Measurements from 0.5 mJ-10 J, single shot and 1-50 Hz
- Displays Joules, average power, and repetition rate
- Large aperture, broadband sensor
|
| Specifications |
| Sensor Disk: |
Pyroelectric, 43.2 mm aperture |
| Wavelength Range: |
190 nm to 10.6 µm |
| Energy Range: |
±5% |
| Maximum Average Power: |
10 W |
| Maximum Energy Density: |
50 mJ/cm² (for 193 nm, 15 ns pulse) |
| Pulse Rate: |
Single Pulse or 1-50 Hz |
| Max Pulse Width: |
1 ms |
| Response Time: |
< 1s |
| Battery: |
9 V, >20 hours life |
| Analog Output: |
0-1 V |
| Display Backlight: |
With AC operation only. |
|
LaserMate
Broadband Laser Power Meter |
|
|
- Cost-effective precision CW power measurement
- Choice of sensors for 0.3 mW-150 W power
- Sensors spectrally flat from 250 nm-10.6 µm
- Adjustable needle response
|
|
Description
|
Power Max (W)
|
Power Min (mW)
|
Wavelength Range (µm)
|
Accuracy (Including display) % of reading
|
Accuracy (Including display) ± LSD
|
Maximum W/cm2
|
Sensor Diameter (mm)
|
| LaserMate Sensor |
1 |
0.3 |
0.25 - 1.5 |
5 |
2 |
200 |
9.6 |
| LaserMate Sensor |
3 |
10 |
0.25 - 10.6 |
5 |
2 |
200 |
17.8 |
| LaserMate Sensor |
10 |
10 |
0.25 - 10.6 |
5 |
2 |
200 |
15.2 |
| LaserMate Sensor |
20* |
100 |
0.25 - 10.6 |
5 |
2 |
200 |
19.1 |
| LaserMate Sensor |
30 |
100 |
0.25 - 10.6 |
5 |
2 |
200 |
19.1 |
| LaserMate Sensor |
100 |
100 |
0.25 - 10.6 |
5 |
2 |
200 |
19.1 |
| LaserMate Sensor |
150** |
100 |
0.25 - 10.6 |
7 |
2 |
6000 |
19.1 |
|
Specifications
|
| Response Time: |
<1 s, adjustable |
| Battery: |
9 V, >200 hours life |
| Analog Output: |
0-1 V |
| Display Backlighting: |
With digital display and AC operation only |
|
FieldMaster
Laser Power and Energy Meter for use with SmartSensors |
|
|
- Choice of over 30 power and energy SmartSensors
- CW power measurements from 10 nm to 5 kW
- Pulse energy measurements from 0.5 mJ to 20 J
- Sensors for wavelenghts from 190 nm to 20 µm
|
| Specifications |
| Accuracy: |
±2% ±2 LSD meter only. Net accuracy with any head is head accuracy plus instrument accuracy. See SmartSensor section. |
| Display: |
Three digit liquid crystal display (LCD) and conventional moving coil meter. Contrast can be adjusted via push buttons. |
| Power Requirements: |
|
| AC Operation: |
115 VAC 50/60 Hz |
| 10 VA Maximum |
| 230 VAC 50/60 Hz |
| 7.5 VA Maximum |
| 1.5 VA Typical |
| Memory: |
Retains configuration information when turned off (wavelength correction values, display contrast etc.) |
| Operating Temperature: |
5-40 °C |
| Safety Features: |
Visual and audible sensor over-temperture and sensor over-range alarms. Has protective cover which doubles as a base. Also, an optional soft carrying case is available. |
| Size: |
190 x 117 x 46 mm |
| Weight: |
737 grams with batteries |
| DC Operation: |
Uses 2 standard 9 V transistor radio batteries. Unit is fully functional with one battery. Use 2 batteries for maximum working life before battery change. Low battery condition is indicated at 5% of battey life remaining. |
| 1.5 VA Typical |
Working life of batteries: 8 hours with 2 each Duracell MN1604 or ID1604
4 hours with 1 each Duracell MN1604 or ID1604 |
|
FieldMaster-GS
Laser Power and Energy Meter for use with SmartSensors |
|
|
- Choice of over 30 SmartSensors™ for wavelengths from 190 nm-20 µm
- CW power measurements from 10 nW-5 kW
- Pulse energy measurements from 1 µJ-95 J
- 70 x 60 mm digital display with analog tuning needle
- Beam statistics and postion displays
- RS-232 control and analog out
|
| Specifications |
| Accuracy - Display Unit: |
±1% of reading, ±2 LSD |
| Accuracy - System: |
sum of display and sensor accuracies |
| Pulse Capture Rate: |
10 Hz max. |
| CW Sample Rate: |
10 Hz max. |
| Tuning Needle Rate: |
10 Hz |
| Digits Update Rate: |
2 Hz |
| Size: |
190 x 117 x 46 mm |
| Weight: |
784 g |
| Operating Temperature: |
5-40° C |
| Analog Out: |
0-1 V ±2%, 5 Hz |
| Battery life: |
8 hours continuous use (4 hours with backlight) |

|
Ultima LabMaster
Laser Power and Energy Analyzer System for SmartSensors |
|
|
- Single or dual channels with choice of 30 power and energy SmartSensors™
- CW power measurements from 10 nW-5 kW
- Pulse energy measurements from 100 µJ-95 J
- Sensors for wavelengths from 190 nm-20 µm
- Ratio/difference, RMS noise, and beam position measurements
|
| Specifications |
| Display Type: |
High speed, high contrast liquid crystal display. Wide viewing angle, 256 x 128 pixels. |
| Display Options: |
Software control of contrast, normal or reverse display, and screen backlighting. |
| Update Rate: |
<1 second |
| Display Accuracy: |
±1% ±2 LSD (Must be added to detector accuracy for total system accuracy.) |
| Interface: |
RS-232 (300, 1200, 4800, 9600 baud), GPIB (IEEE-488.2)* |
| Analog Out*: |
0-1 V, ±2%
Computer Correct: 5H
Full Bandwidth: 50 KHz (optional, for Semiconductor detectors only) |
| Printer*: |
Parallel, compatible with Epson, IBM Proprinter, HP jet printers. Auxillary Out (alarm signals): 0-5 V, TTL compatible |
| Auxillary Out (alarm signals): |
0-5 V, TTL compatible |
| Pulse Sensor (maximum pulse capture rate): |
500 Hz dual channel, 1 kHz single channel |
| Semiconductor Sensor*: |
RMS Noise Measurement:5% accuracy, 20 Hz-50 kHz bandwidthth a crest factor of 6.Selectable reading averaging:10 Hz or100 Hz |
| Trend: |
2000 points per channel Pulse or Time acquisition modes |
| Real Time Statistics: |
10 Hz acquisition for CW detectors. Up to 500 Hz acquisition for pulse dual channel. Up to 1 kHz acquisition for pulse single channel. |
| Power Requirements: |
AC Operation: 100-240 VAC, 50/60
DC Operation: 9 VDC, 1 A |
| * Note: Features not available with single channel LabMaster Ultima. |
| Description |
Channels |
Analog Output |
Computer Connections |
| Ultima LabMaster 1 Channel* |
1 |
Standard |
RS-232 |
| LabMaster 2 Channel Enhanced* |
2 |
Standard & Fast |
RS-232, Printer, IEEE-488 |
| Ultima/Windows Connection Kit |
- |
- |
- |
| * Supplied with battery, AC adapter, user manual, certificate of calibration and one year warranty. |
|
SmartSensors
For Use with FieldMaster, FieldMaster-GS and Ultima LabMaster |
|
|
- Sensors for power and average power measurements
- Sensors for single pulse and repetitive pulse energy
- Sensors for RMS noise and beam position measurements
|
| Selecting a SmartSensor |
| Measurement Requirement |
Measurement Range |
Sensor Type |
Notes |
| CW Laser Power |
1 mW to 5 kW |
Thermal |
|
| 10 nW to 5 W |
Semiconductor |
|
| Average Power of Pulse Train |
|
|
|
| >10 Hz |
1 mW to 5 kW |
Thermal |
|
| >30 Hz |
10 nW to 5 W |
Semiconductor |
Ultima LabMaster only |
| 1-400 Hz |
1 µW to 10 W |
Pyroelectric |
Ultima LabMaster and Field Master GS |
| Single Shot Pulse Energy |
|
|
|
| |
0.15 mJ - 50 J |
Thermal |
Ultima LabMaster and Field Master GS |
| |
100 µJ - 20 J |
Pyroelectric |
0.5 mJ minimum on Field Master |
| Pulse Train Pulse Engery |
|
|
|
| 1-400 Hz Pulse Repetition Rate |
100 µJ - 20 J |
Pyroelectric |
Ultima LabMaster only |
| 1-400 Hz with max 10 Hz sampling |
100 µJ - 20 J |
Pyroelectric |
FieldMaster GS |
| 1-50 Hz with max 0.3 Hz sampling |
0.5 µJ - 20 J |
Pyroelectric |
FieldMaster |
| Beam Position |
See Below |
Thermal |
Ultima LabMaster and FieldMaster GS |
| RMS Noise |
See Below |
Semiconductor |
Ultima LabMaster only |
Semiconducter SmartSensors  |
|
Name
|
Power, Max (mW)
|
Power, Min (µW)
|
Power, Resolution (nW)
|
Aperture (mm)
|
Spectral Range (µm)
|
Accuracy (±%)
|
Maximum Power Density (W/cm²)
|
Max Power with Attenuator (W)
|
| LM-2 UV |
30 |
0.01 |
1.00 |
6.0 |
0.25 - 0.4 |
(Note F) 8, 5 |
0.3 |
NA |
| LM-2 VIS |
50 |
0.01 |
1.00 |
7.9 |
0.4 - 1.064 |
(Note F) 5, 3 |
1 |
5 |
| LM-2 IR |
10 |
0.5 z |
1.00 |
5.0 |
0.8 - 1.55 |
(Note F) 4.5, 2 |
0.5 |
5 |
(F) Value to the left is for Ultima LabMaster and FieldMaster-GS, value to the right is for FieldMaster.
(z) 1 µW for FieldMaster. |
Pyroelectric SmartSensors  |
|
| » Show Table (New Window) |
| Volume Absorber Disk Replacement Kits |
| Description |
| Disk Replacement Kit for 33-0993 (UV 0.19 - 0.35 µm) |
| Disk Replacement Kit for 33-0993 (VIS 0.35 - 1.1 µm) |
| Disk Replacement Kit for 33-0993 (IR 1.0 - 6.0 µm) |
| Disk Replacement Kit for 33-1017 (UV 0.19 - 0.35 µm) |
| Disk Replacement Kit for 33-1017 (VIS 0.35 - 1.1 µm) |
| Disk Replacement Kit for 33-1017 (IR 1.0 - 6.0 µm) |
|
LaserPAD
Laser Power Analysis Display System |
|
|
- Complete PC and handheld PDA based Laser Power Measurement
- Up to 4 measurement channels standard for PC’s (more for OEM configurations)
- Choice of over 25 SmartSensors™ for wavelengths from 190 nm to 10.6 µm
- NIST Traceable Calibration, ISO and CE Compliant
- CW power measurement from 10 nW to 5 kW
- Full Statistical and Power Trend Analysis
|
| Specifications |
| Accuracy |
Display: ±1% of reading ±2 LSD.
System: sum of display and sensor accuracies. |
| CW Sample Rate |
10 Hz max. |
| Ranges |
Microprocessor controlled.
Ranges determined by EEPROM in SmartSensor heads. |
| Communication |
USB and RS-232 Communication between Host Computer and
SmartSensor Interface Module.1 |
| Memory |
The SSIM has the capability to buffer multiple commands to
process in a serial order.2 |
| Operating Temperature |
5°C to 40°C |
| Safety Features |
Sensor over-temperature, alignment and over-range events. |
| Size (LxWxH) |
133x127x38 mm |
| Weight |
400 g with batteries. |
| AC Wall Plug Input Requirements |
100-240V, ~0.2 A, 50-60 Hz |
| 6V Internal Rechargeable Battery Pack |
Recharges automatically during AC operation.
Battery life: 12 hours typical. Complete recharge cycle is 14 hours. |

|
dBCheck
Handheld Fiber Power Meter |
|
|
- Power measurement from -60 dBm (1 nW) to 3 dBm (2 mW)
- 3 digit LCD display with Power Unit Indicator for µW, mW and dBm
- ±5% calibrated accuracy from 850 to 1700 nm
|
| Specifications |
| Sensor Type |
InGaAs Cell |
| Spectral Response |
850 - 1700 nm |
| Accuracy |
±5% (±0.3 dB) |
| Max. CW Power |
3 dBm (2 mW) |
| Min. Detectable Power |
-60 dBm (1 nW) |
| Min. Power Resolution |
0.1 dB (1 nW) |
| Aperture Size |
1.0 mm |
| Fiber Ferrule Diameter |
2.5 mm |
| Fiber Connector Compatibility |
ST, FC and SC type |
| Measurement Display |
3 Digit LCD with Power Unit Indicator |
| Display Power Indicator |
µW, mW and dBm |
| Update Rate |
3 Hz |
| Wavelength Selection Display |
850 to 999 (for 850 nm to 999 nm) |
| |
-000 to -700 (for 1000 nm to 1700 nm) |
| Power On Delay (time to first sample) |
2 sec. |
| Display Hold Time |
18 sec. |
| Battery Life |
1,000 Hr. |
| |
(180,000 measurements at 20 sec./sample) |
| Size (max. dimensions) |
168 mm L x 24 mm W x 20 mm T |
|
(6.61 L x 0.95W x 0.79T) |
| Weight |
44 g (1.55 oz.) |
|
|